한국해양대학교

Detailed Information

Metadata Downloads

저압용 유도전동기에서 미소부분방전 측정에 관한 연구

DC Field Value Language
dc.contributor.author 서황동 -
dc.date.accessioned 2017-02-22T06:55:53Z -
dc.date.available 2017-02-22T06:55:53Z -
dc.date.issued 2005 -
dc.date.submitted 56822-12-26 -
dc.identifier.uri http://kmou.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000002175750 ko_KR
dc.identifier.uri http://repository.kmou.ac.kr/handle/2014.oak/10038 -
dc.description.abstract This thesis deals with a partial discharge(PD) measurement techniques to apply a PD test to low-voltage induction motors as a part of quality assurance. The objective of this study is to develop a PD measurement system, which can detect charge below 1PC, to prevent insulation degradation of the test sample from the test voltage. PD pulses are obtained by a straight detection principle considering the wide use in fields. The fabricated PD measurement system is composed of a coupling network with a discharge free capacitor and a detection impedance, a low-noise amplifier, and an associated electronics. The low cutoff frequency of the detection circuit is set at 1MHz(-3dB) to attenuate AC voltage by 270dB and to pass discharge pulses only without any distortion. A shielding enclosure of Ni-Cu double structure and a high voltage filter having a high cutoff frequency of 3.5kHz were designed to get a better measurement condition against radiation and conduction noises from outside. The PD measurement system was tested to noise intereference and the peak noise level appeared 3mVp-p. Calibrations of the PD measurement system were carried out according to the IEC 60270 and the calculated sensitivities by a standard calibrator on low-voltage induction motors were 22.3mV/pC for 1φ 0.5HP and 11.4mV/pC for 3φ 5HP, respectively. Also, the sensitivity to the positive and negative polarity pulses were same in ranges from 1pC to 50pC. In the PD test on the motors, it was confirmed that the polarity of PD pulses changes depending on the shape of a void or a interface, and an apparent charge of 0.7pC was measured at AC 664Vpeak. -
dc.description.tableofcontents 목 차 ⅰ 그림 목차 ⅲ Abstract ⅴ 제 1 장 서 론 1 1.1 연구배경 1 1.2 연구목적 및 내용 2 제 2 장 이 론 4 2.1 절연열화기구 및 평가기술 4 2.2 부분방전의 발생 6 2.3 부분방전의 검출 12 제 3 장 설계 및 제작 17 3.1 검출회로 17 3.1.1 결합회로망 18 3.1.2 증폭회로 20 3.2 잡음 대책 22 3.3 측정시스템 구성 26 제 4 장 실험 및 고찰 28 4.1 측정시스템 평가 28 4.2 유도전동기에서 부분방전 측정 33 제 5 장 결 론 51 참 고 문 헌 53 -
dc.language kor -
dc.publisher 한국해양대학교 대학원 -
dc.title 저압용 유도전동기에서 미소부분방전 측정에 관한 연구 -
dc.title.alternative A Study on the Measurement of Small Partial Discharges in Low-voltage Induction Motors -
dc.type Thesis -
dc.date.awarded 2006-02 -
dc.contributor.alternativeName Hwang Dong Seo -
Appears in Collections:
전기전자공학과 > Thesis
Files in This Item:
000002175750.pdf Download

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse