한국해양대학교

Detailed Information

Metadata Downloads

회전형 Field Mill을 이용한 뇌경보시스템 개발에 관한 연구

DC Field Value Language
dc.contributor.author 千相奎 -
dc.date.accessioned 2017-02-22T07:26:38Z -
dc.date.available 2017-02-22T07:26:38Z -
dc.date.issued 2001 -
dc.date.submitted 56797-10-27 -
dc.identifier.uri http://kmou.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000002174100 ko_KR
dc.identifier.uri http://repository.kmou.ac.kr/handle/2014.oak/10820 -
dc.description.abstract The objection of this study is to develop a lightning warning system based on the measurement of electric field intensity on the ground level. In this thesis, changes of the electric field intensity formed by thunderclouds are theoretically described. Also two types of calibration system, such as a cylindrical guard electrodes and a parallel-plate electrodes, are proposed to determine the sensitivity and frequency bandwidth of the lightning warning system. In order to accomplish the high sensitive lightning warning system, the principles and design rules of a rotation-type field mill are studied. The lightning warning system consists of the rotation-type field mill as an electric field sensor, an impedance changer, and a two-stage amplifier. The field mill is composed of two isolated electrode vanes, a grounded stator and a rotor. The impedance changer necessary to maximize the time-constant of the lightning warning system is designed by using an operational amplifier(CA3130) with extremely high input impedance of 1.5 [TΩ]. From the calibration experiment, the frequency bandwidth and the sensitivity of the field mill are DC ∼ 200 [Hz] and 0.267 [mV/V/m], respectively. Maximum resolution of the developed lightning warning system is about 73 [V/m], and can be measured the electric field strength up to about 18.7 [kV/m]. For the purpose of measuring a higher level of the electric field strength, the sensitivity can be conveniently adjusted with a voltage divider in parallel connected to the output of the impedance changer. To ensure the sensing ability of the developed lightning warning system in the actual situation, computer simulation using thundercloud models was carried out, and the result showed that the system can monitor the movement of thunderclouds within 6 [km] from the observation site. -
dc.description.tableofcontents Abstract = ⅱ 그림 및 표 목차 = ⅳ 제 1 장 서론 = 1 제 2 장 이론 = 5 2.1 뇌운에 의한 대지전계 변화 = 5 2.2 대지전계 측정장치 = 11 2.3 회전형 필드 밀의 원리 = 14 제 3 장 뇌경보시스템의 구성 = 21 3.1 회전형 필드 밀을 이용한 대지전계 측정 = 21 3.2 뇌경보시스템 = 24 제 4 장 교정장치 및 방법 = 27 4.1 교정장치의 설계 및 제작 = 27 4.2 교정방법 = 32 제 5 장 실험결과 및 고찰 = 34 5.1 주파수 대역 및 응답감도 = 34 5.2 뇌경보 능력에 대한 이론적 고찰 = 38 제 6 장 결론 = 42 참고 문헌 = 44 부록 = 48 -
dc.publisher 한국해양대학교 대학원 -
dc.title 회전형 Field Mill을 이용한 뇌경보시스템 개발에 관한 연구 -
dc.title.alternative (A) Study on the Development of a Lightning Warning System Utilizing a Rotation-type Field Mill -
dc.type Thesis -
Appears in Collections:
전기공학과 > Thesis
Files in This Item:
000002174100.pdf Download

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse