한국해양대학교

Detailed Information

Metadata Downloads

Tomographic-imaging 기술을 이용한 연성 필름이 부착된 실린더의 후류 및 연성 필름 운동 동시계측

DC Field Value Language
dc.contributor.author 권성용 -
dc.date.accessioned 2017-02-22T05:18:09Z -
dc.date.available 2017-02-22T05:18:09Z -
dc.date.issued 2012 -
dc.date.submitted 56989-07-02 -
dc.identifier.uri http://kmou.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000002174460 ko_KR
dc.identifier.uri http://repository.kmou.ac.kr/handle/2014.oak/8491 -
dc.description.abstract Simultaneous Measurements of the Wake Flow of a Circular Cylinder with a Flexible Film and Its Motions using Tomographic Imaging Technique by Seong yong, Kwon Department of Refrigeration and Air-Conditioning Engineering Graduate School of Korea Maritime University Abstract Many engineers have tried to analyze the interactions between fluid flows and structures motions. In order to understand the flow-structure interaction(FSI), the energy given by the fluid to the structure should be evaluated, and the energy given by the structure's motion or vibration to the fluid should also be evaluated. To do this, the vector field of the fluid should be measured, and the motion of the structure should be measured, simultaneously. Since the flow fields are generally strong three-dimensional, the measurement for the flow field should be made in three dimension. There have been many techniques for three-dimensional measurements, such as 3D-PTV, Stereoscopic PIV, Holographic-PIV, and Tomographic PIV. Among them, the Tomographic PIV is widely focused nowadays for its measurement performances for three-dimensional flows. This allowed researchers to measure three-dimensional flow motion with high resolution. However, the demerit of this technique was the filtering effect coming from the PIV principle. This implies that the small vortices were apt to be filtered out by the interrogation window of PIV, and detailed structures were easily unmeasurable. In order to overcome this drawback, a Tomographic-PTV based technique is introduced in this study. With the constructed Tomographic-PTV technique, the wake flow of a cylinder body with a flexible film was measured, and simultaneously the motion of the film was measured. The film is made of Loden with configurations of 35mm(W) * 100mm(L) * 0.024(T). This was attached on to a cylinder (d=30mm). The Reynolds number tested was 2447. The measurement system consists of an Ar-ion laser(8W), a high speed camera(1024*992pixel, 200fps) and a host computer. The interactions between the wake flow and the film motion were investigated with the measured results. -
dc.description.tableofcontents 그림 목차 ⅲ 사용 기호 ⅵ Abstract ⅷ 제1장 서 론 1.1 연구배경 1 1.2 연구목적과 구성 8 제2장 CT(Computed Tomographic)의 개요 2.1 Computed Tomography의 변천사 9 2.2 Computed Tomography 원리 15 2.3 라돈 변환(Radon Transform) 변환 19 2.4 라돈 변환의 회전각 추출 및 보정 22 제3장 Tomographic PIV 3.1 3D PTV와 Tomographic PIV 23 3.2 3차원 계측 원리 25 3.3 카메라 영상위치 결정 30 제4장 영상처리(Image Processing) 4.1 잡음제거(Image Denosing) 34 4.2 영상분리(Image Segmentation) 35 제5장 Volume 재구성 모델(Volume Reconstruction Model) 5.1 ART 법과 MART 법 42 제6장 유체-구조 연동 동시측정 시스템 6.1 계측 원리 47 제7장 연성판이 부착된 실린더 후류 실험 7.1 실험장치 및 구성 49 7.2 실험 결과 및 고찰 54 제8장 결론 61 참고논문 62 -
dc.language kor -
dc.publisher 한국해양대학교 공과대학 -
dc.title Tomographic-imaging 기술을 이용한 연성 필름이 부착된 실린더의 후류 및 연성 필름 운동 동시계측 -
dc.title.alternative Simultaneous Measurements of the Wake Flow of a Circular Cylinder with a Flexible Film and Its Motions using Tomographic Imaging Technique -
dc.type Thesis -
dc.date.awarded 2012-08 -
Appears in Collections:
냉동공조공학과 > Thesis
Files in This Item:
000002174460.pdf Download

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse