한국해양대학교

Detailed Information

Metadata Downloads

인간의 움직임을 적용한 인체크기의 이족보행로봇 설계 및 기구학 해석

DC Field Value Language
dc.contributor.author 이종훈 -
dc.date.accessioned 2017-02-22T06:52:54Z -
dc.date.available 2017-02-22T06:52:54Z -
dc.date.issued 2008 -
dc.date.submitted 56877-07-05 -
dc.identifier.uri http://kmou.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000002175688 ko_KR
dc.identifier.uri http://repository.kmou.ac.kr/handle/2014.oak/9956 -
dc.description.abstract This thesis is about 27 degree-of-freedom humanoid robot named KUBIR-3 which has height of 170cm and weight of 72kgf. KUBIR-3 is composed of four parts: the head, body, arms and legs. The head part is composed of two degree-of-freedom which are directly connected by the actuator motor and speed reducer. The body was designed to have one degree-of-freedom to give roll motion of the robot. The arms were designed to have six d.o.f where three joints are composed of the four-bar-link joint actuator and the other were designed to have the actuator motor with the speed reducer as the harmonic driver. The legs were designed to have six d.o.f. where three joints are composed of the four-bar-link joint actuator and the other were designed to have the actuator motor with the speed reducer as the harmonic driver. At the shoulder, elbow, and wrist joints of arms and at the thigh, knee, and ankle joints of legs, the four-bar link joint actuator was applied to transfer the heavy loads. To analyze the kinematics of KUBIR-3, the D-H convention was applied to the joints of the robot. For this, the center of the robot body was selected as the base coordinate. Based on this, the relative positions of the arms and legs were defined. Also, using this, the inverse kinematics analysis was made. The strain and stress analyses for links of the arm and leg of the KUBIR-3 were made by the FEM analysis using the CATIA. To do these, modeling of the arm and leg was made. The results of the simulation showed the safe design of the link of the arm and leg. For the analysis of the four-bar link joint of KUBIR-3, static force equation according to the load torque was analyzed. The analyzed data of this equation showed the validity of the appropriate choosing of the actuator motors for supporting heavy loads. The case molding of the KUBIR-3 was designed and constructed based on the 3D modeling using the CATIA. -
dc.description.tableofcontents 목 차 Abstract 기호설명 그림목차 표목차 제 1 장 서론 제 2 장 이족보행로봇의 구성 2.1 이족보행로봇 전체시스템 구성 2.2 이족보행로봇 머리 기구부 구성 2.3 이족보행로봇 허리 기구부 구성 2.4 이족보행로봇 팔 기구부 구성 2.5 이족보행로봇 하체 기구부 구성 2.6 이족보행로봇 제어시스템 구성 제 3 장 이족보행로봇의 기구학 해석 3.1 이족보행로봇 D-H 구성 3.2 이족보행로봇 머리 기구학 해석 3.3 이족보행로봇 팔 기구학 해석 3.4 이족보행로봇 다리 기구학 해석 3.5 이족보행로봇의 기구학적 상호관계 적용 제 4 장 이족보행로봇의 관절 구동기 해석 4.1 4절 링크의 관절 관계식 4.2 4절 링크 구조의 관절 구동기 부하토크 해석 4.3 4절 링크 구조의 관절 구동기 해석 데이터 제 5 장 이족보행로봇의 기구부 구조해석 5.1 유한요소 모델 5.2 유한요소 해석 제 6 장 이족보행로봇의 외장케이스 설계 6.1 외장케이스의 3D 설계와 금형 제품 6.2 외장케이스의 경량화 제 7 장 결론 -
dc.language kor -
dc.publisher 한국해양대학교 -
dc.title 인간의 움직임을 적용한 인체크기의 이족보행로봇 설계 및 기구학 해석 -
dc.type Thesis -
dc.date.awarded 2008-02 -
Appears in Collections:
기계공학과 > Thesis
Files in This Item:
000002175688.pdf Download

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse