한국해양대학교

Detailed Information

Metadata Downloads

기액이상류시의 펌프특성실험에 관한 기초연구

Title
기액이상류시의 펌프특성실험에 관한 기초연구
Alternative Title
A Basic Study on the Pump Characteristics Experiments Operating in Air-Water Two-Phase Flow
Author(s)
김성윤
Issued Date
2006
Publisher
한국해양대학교
URI
http://kmou.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000002174719
http://repository.kmou.ac.kr/handle/2014.oak/8794
Abstract
In a general centrifugal pump, if it is operated for a two-phase flow the activity of the impeller usually degrades and occasionally losses its function.

However, the effect of break down of centrifugal pump due to entrained air has not been clarified yet. Thus, air-water two-phase flow experimental apparatus was installed to acquire basic data. This paper tries to analyze the single-phase flow and air-water two-phase flow characteristics through this air-water two-phase flow experimental apparatus. The pump rpm and the shaft torque are measured by rpm sensor and torque sensor. The casing is made up with transparency acrylic for confirmation the flow patterns. According to void fraction, mass and shape of impeller, the pump characteristics under a single-phase flow were measured. The test pump's maximum rpm, head, kW are 1,750, 15m and 1.5kW, respectively. The performance results of a single-stage closed-type centrifugal pump satisfied reappearance and reliance. Also, in a single-phase flow, compare to semi-open type impeller, closed-type impeller has superior and efficiency. But in air-water two-phase flow, the rate of decrease of efficiency and head decreases.
Appears in Collections:
기관시스템공학과 > Thesis
Files in This Item:
000002174719.pdf Download

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse